Cardiac computed tomography angiography (CCTA) is a commonly used diagnostic imaging tool for cardiovascular disease. Despite constant improvements to imaging technologies, the radiation dose to patients remains a concern when using this procedure. Diagnostic reference levels (DRLs) are used as a trigger to identify and alert individual facilities that are using high doses during CT. This study aims to assess patient radiation dose and establish new national DRLs (NDRL) associated with CCTA in Saudi clinical practices. A structured booklet survey was designed for recording patient and scanning protocols during CCTA procedures. The data were collected retrospectively from the participating centres. NDRLs for CCTA were defined as the 75th and 25th of volumetric CT dose index (CTDIvol) and dose length product (DLP). Specific DRLs based on two main ECG-gating modes were also proposed. Data sets related to 197 CCTAs with a mean weight of 77 kg were analysed in detail. The DRL values for CTDIvol and DLP for prospective gating mode and retrospective gating mode were 29 and 62 mGy and 393 and 1057 mGy cm, respectively. NDRLs for CCTA in Saudi Arabia are comparable or slightly lower than European DRLs due to the current use of dose-saving technology. There are major variations in patient doses during CCTA due to differences in CT scanners, scanning modes and departmental CCTA protocols.
机译:心脏计算机断层造影血管造影(CCTA)是心血管疾病的常用诊断成像工具。尽管对成像技术进行了不断的改进,但是使用此程序时,仍然需要考虑对患者的辐射剂量。诊断参考水平(DRL)用作触发条件,以识别和警告在CT期间使用高剂量的各个设施。这项研究旨在评估患者的辐射剂量,并在沙特的临床实践中建立与CCTA相关的新的国家DRL(NDRL)。结构化的小册子调查旨在记录CCTA程序中的患者和扫描协议。数据是从参与中心回顾性收集的。 CCTA的NDRL定义为体积CT剂量指数(CTDIvol)和剂量长度乘积(DLP)的75和25。还提出了基于两种主要ECG门控模式的特定DRL。详细分析了与197个CCTA有关的数据集,平均体重为77 kg。对于预期门控模式和回顾门控模式,CTDIvol和DLP的DRL值分别为29和62 mGy和393和1057 mGy cm。由于目前使用的是节省剂量的技术,沙特阿拉伯CCTA的NDRL与欧洲的DRL相当或略低。由于CT扫描仪,扫描模式和部门CCTA协议的差异,CCTA期间的患者剂量存在很大差异。

著录项

  • 来源
    《Radiation Protection Dosimetry 》 |2018年第2期| 129-134| 共6页
  • 作者单位

    Univ Sydney, Fac Hlth Sci, M205,Cumberland Campus,75 East St, Sydney, NSW 2141, Australia;

    Univ Sydney, Fac Hlth Sci, M205,Cumberland Campus,75 East St, Sydney, NSW 2141, Australia;

    Univ Sydney, Fac Hlth Sci, M205,Cumberland Campus,75 East St, Sydney, NSW 2141, Australia;

    Univ Sydney, Fac Hlth Sci, M205,Cumberland Campus,75 East St, Sydney, NSW 2141, Australia;

    Univ Sydney, Fac Hlth Sci, M205,Cumberland Campus,75 East St, Sydney, NSW 2141, Australia;

  • 收录信息 美国《科学引文索引》(SCI);美国《化学文摘》(CA);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号