This article presents experimental results obtained by the investigation of the efficiency of radioactive decontamination of a metal surface with alkyd and epoxy-urethane coating systems, which are used for the painting of military equipment. During the evaluation of the efficiency of decontamination, the impact of contaminants on the coating was not examined but the amount of contaminants residual after decontamination was, and was determined by activity measurements of the surface. The samples for testing were painted aluminum plates contaminated by liquid solutions of radioactive isotopes 60Co, 133Ba, 152Eu and 241Am (A=12297.91Â Bq/ml). Decontamination of contaminated samples was performed with 0.5% detergent solution on the basis of synthetic surfactants. The activity measurements of samples were conducted using gamma spectroscopy system with a high-resolution high-purity germanium (HPGe) detector of relative efficiency of 50% at 60Co (1.33Â MeV). The degree of removal of the radioactivity on the samples was observed as an indicator of the efficiency of decontamination. A comparison of the results is presented in relation to the retention time of the contamination on the surface coating, which is an important factor for the efficiency of decontamination. The samples with an alkyd coating system showed better efficiency of decontamination than the samples with the epoxy-urethane coating system, although the coatings based on epoxy and urethane resin were superior in relation to the alkyd in terms of protection, decorative characteristics and chemical resistance. The difference in the efficiency of decontamination for the examined coatings increases almost linearly in relation to the retention time of the contaminants in the coating.View full textDownload full textKeywordscontamination, decontamination, alkyd coating, epoxy and urethane coating, gamma spectroscopy, the efficiency of decontaminationRelated var addthis_config = { ui_cobrand: "Taylor & Francis Online", services_compact: "citeulike,netvibes,twitter,technorati,delicious,linkedin,facebook,stumbleupon,digg,google,more", pubid: "ra-4dff56cd6bb1830b" }; Add to shortlist Link Permalink http://dx.doi.org/10.1080/10420150903410276
机译:本文介绍了通过研究用醇酸和环氧-氨基甲酸酯涂层系统对金属表面进行放射性净化处理的效率而获得的实验结果,该系统用于军事装备的涂漆。在评估去污效率的过程中,未检查污染物对涂层的影响,但检查了去污后残留的污染物量,并通过表面活性测量来确定。测试样品为涂有铝的板,该板被放射性同位素 60 Co, 133 Ba, 152 Eu和 241 < / sup> Am(A = 12297.91 Bq / ml)。在合成表面活性剂的基础上,用0.5%的洗涤剂溶液对受污染的样品进行去污。样品的活性测量是使用伽马光谱系统和高分辨率的高纯度锗(HPGe)检测器进行的,相对检测器在 60 Co(1.33 MeV)下的相对效率为50%。观察到样品上放射性的去除程度作为去污效率的指标。将结果与污染物在表面涂层上的保留时间进行比较,这是提高去污效率的重要因素。具有醇酸涂层体系的样品比具有环氧-氨基甲酸酯涂层体系的样品表现出更好的去污效率,尽管基于环氧和聚氨酯树脂的涂层在保护,装饰特性和耐化学性方面优于醇酸。待检查涂层的去污效率差异与污染物在涂层中的保留时间有关,呈线性增长。查看全文下载全文关键词去污,去污,醇酸涂料,环氧和聚氨酯涂料,γ光谱法,去污效率相关var addthis_config = {ui_cobrand:“泰勒和弗朗西斯在线”,servicescompact:“ citeulike,netvibes,twitter,technorati,delicious,linkedin,facebook,stumbleupon,digg,google,更多”,发布号:“ ra-4dff56cd6bb1830b”};添加到候选列表链接永久链接http://dx.doi.org/10.1080/10420150903410276

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号