首页> 外文期刊>日本建築学会构造系論文集 >Structural Performance Of Steel Beam-To-Concrete Filled Steel Tubular Column Connections Using High Strength Materials
【24h】

Structural Performance Of Steel Beam-To-Concrete Filled Steel Tubular Column Connections Using High Strength Materials

机译:使用高强度材料的钢梁到混凝土钢管柱连接的结构性能

获取原文
获取原文并翻译 | 示例
           

摘要

As a part of the U.S.-Japan Cooperative Earthquake Engineering Research Program on Composite and Hybrid Structures, ten concrete filled steel tubular column (CFT) to structural steel beam connections were tested under reversed cyclic loading to investigate the effects of high material strength, configuration and geometry of connections, column axial load and loading direction on the shear strengths and deformation capacity. This paper presents the test results and discusses the shear behavior of CFT connections. All the specimens reached their ultimate panel shear strengths at least to be 1.3 times of the design panel ultimate strengths by AIJ-SRC (1987)formula, whose scope of application is for medium to low material strengths and not for high material strengths tested in this study.
机译:作为美日复合材料和混合结构合作地震工程研究计划的一部分,在反向循环荷载下测试了十个钢管混凝土柱(CFT)与结构钢梁的连接,以研究高材料强度,结构和结构的影响。连接的几何形状,圆柱轴向载荷和载荷方向对剪切强度和变形能力的影响。本文介绍了测试结果并讨论了CFT连接的剪切行为。通过AIJ-SRC(1987)公式,所有试样均达到其最终面板抗剪强度至少是设计面板抗剪强度的1.3倍,其适用范围适用于中低材料强度,而不适用于在此测试的高材料强度研究。