The clocking effect, known as a potential means to improve the aerodynamic performance of the turbomachinery, has been investigated widely in the multistage axial turbomachinery, but little reported on the radial turbomachinery. In the present paper, an experimental investigation was made on the vane clocking effect between the inlet guide vanes and the vaned diffuser in a medium-speed centrifugal compressor. The measured data show that the vane clocking has an effect on the aerodynamic performance of the researched centrifugal compressor stage. At the design point, the maximum efficiency variation is about 0.52 points and the maximum total pressure ratio variation is 0.004. When the inlet guide vane's stagger angle was adjusted to -45°, the vane clocking effect is strengthened. The maximum efficiency and total pressure ratio variation for the design point, respectively, are 0.67 points and 0.006, and for the low flow rate point even, respectively, increases to 0.90 points and 0.007. The wake characteristics show that the maximum efficiency variation always arises at a similar clocking configuration, in which the upstream inlet guide vanes wake was detected to impinge on the diffuser blade leading edge. In addition, the profile pressure distribution on the diffuser blade was measured in detail and the blade loading analysis shows that there is no measureable variation for the vane clocking effect on the steady diffuser blade loading.
机译:在多级轴流式涡轮机中,人们广泛地研究了时钟效应,即提高涡轮机气动性能的潜在手段,但对径向式涡轮机的报道很少。在本文中,对中速离心压缩机中的进口导向叶片和叶片式扩散器之间的叶片计时效应进行了实验研究。实测数据表明,叶片计时对所研究的离心压缩机级的空气动力性能有影响。在设计点,最大效率变化约为0.52点,最大总压力比变化为0.004。将进口导流叶片的交错角调整为-45°时,增强了叶片计时功能。设计点的最大效率和总压力比变化分别为0.67点和0.006,而低流量点甚至分别增加到0.90点和0.007。尾流特性表明,最大效率变化总是在类似的时钟配置下出现,其中检测到上游入口导向叶片尾流撞击在扩散器叶片前缘上。另外,详细测量了扩压器叶片上的轮廓压力分布,叶片负荷分析表明,叶片计时对稳定的扩压器叶片负荷没有可测量的变化。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号