首页> 外文期刊>Proceedings of the Institution of Civil Engineers >Pin-bearing strengths for bolted connections in fibre-reinforced polymer structures
【24h】

Pin-bearing strengths for bolted connections in fibre-reinforced polymer structures

机译:纤维增强聚合物结构中螺栓连接的销轴承强度

获取原文
获取原文并翻译 | 示例

摘要

Presented in this paper are pin-bearing strengths for pultruded fibre-reinforced polymer materials that are required in order to check the bearing resistance when designing bolted connections. For steel pin diameters up to 16 mm, equivalent test results, at room temperature, using the European standard test method BS EN 13706-2 and another test method (such as ASTM D 5764) are shown not to be significantly different. As the latter method uses much smaller specimen blanks, new pin-bearing strengths can be determined for the web material in a 203 × 203 × 9.5 mm wide flange shape, with the connection force at 0°, 45° or 90° to the direction of pultrusion. An evaluation is made of the test results and recommendations are given on how pin-bearing strengths are to be determined so that they will match the geometries of bolted connections and connection forces found in practice.
机译:本文介绍的是拉挤纤维增强聚合物材料的销轴承强度,在设计螺栓连接时需要检查轴承阻力。对于最大直径为16 mm的钢销,在室温下使用欧洲标准测试方法BS EN 13706-2和另一种测试方法(例如ASTM D 5764)的等效测试结果显示没有显着差异。由于后一种方法使用的样品坯料要小得多,因此可以确定宽203×203×9.5 mm法兰形状的腹板材料的新的销钉承载力,且连接力为0°,45°或90°拉挤成型。对测试结果进行评估,并给出如何确定销轴承强度的建议,以使它们与螺栓连接的几何形状和实际使用中的连接力相匹配。