To provide a standard temperature noise source for use with S-band radiometers, the noise power from the argon discharge tube CV1881 has been calibrated at 2860 Mc/s using radiometer techniques. The absolute value of the effective temperature of the tube with a discharge current of 180 mA, when mounted across a waveguide parallel to the E-plane and properly matched, is 11 140???????° K (15.73 dB) with a maximum error of 260???????° K (0.10 dB), and represents a considerable improvement in accuracy over previous measurements. Since this tube shows a high degree of stability and consistency, it is suggested that it could be used as an absolute standard noise source for the measurement of the noise factor of receivers.
机译:为了提供用于S波段辐射计的标准温度噪声源,已使用辐射计技术将氩气放电管CV1881的噪声功率校准为2860 Mc / s。当安装在与E平面平行且适当匹配的波导上时,放电电流为180 mA时,管的有效温度的绝对值为11 140 ??????°K(15.73 dB),最大误差为260°K?K(0.10 dB),与以前的测量相比,其精度有很大提高。由于该管显示出高度的稳定性和一致性,因此建议将其用作测量接收机噪声因子的绝对标准噪声源。