The operation of an induction motor at one-half normal speed against appreciable load, by means of unbalanced impedance in the secondary circuit, is shown to be a practicable possibility with accurately predictable characteristics. Precautions must be taken to prevent saturation of the main magnetic circuit of the machine, and in some cases it may be essential to limit the injection of low-frequency currents into the supply system. Simple solutions to these problems are described, and it is concluded that the method has sufficient merits to justify its use in certain applications where a speed reduction to about one-half the normal value is required.
机译:借助于次级电路中不平衡的阻抗,感应电动机在正常速度的一半下克服明显的负载运行是可行的,并且具有可精确预测的特性。必须采取预防措施以防止机器的主磁路饱和,并且在某些情况下,必须限制将低频电流注入电源系统。描述了对这些问题的简单解决方案,并得出结论,该方法具有足够的优点,足以证明其在某些需要将速度降低到正常值的一半的应用中是合理的。