首页> 外文期刊>Pramana >A high resolution AMS-injector for the Pelletron in Lund
【24h】

A high resolution AMS-injector for the Pelletron in Lund

机译:隆德Pelletron的高分辨率AMS进样器

获取原文
获取原文并翻译 | 示例
           

摘要

A high resolution injector system has recently been installed at the Lund 3MV tandem Pelletron accelerator. The new injector, designed mainly for ~(26)Al ions, will increase the experimental potential of the Lund AMS facility considerably. High quality energy- and mass-resolution is obtained by using a 90° spherical electrostatic analyzer followed by a 90° magnetic analyzer. The injector is equipped with a high intensity sputtering source with a spherical ionizer. A new analytical technique for acceptance calculations as well as PC-based computational methods have been used in the design of the ion optical system of the new injector. Compared to our old injector system which has a magnetic analyzer with a bending angle of only 15°, the new system has a more than ten times better resolution. The beam optics of the new system is also better designed to match the accelerator acceptance. In this way the ion transmission from the ion source to the detector, for different ions of interest in our AMS programme, has been increased.
机译:最近在隆德3MV串联Pelletron加速器上安装了高分辨率注射器系统。新的注射器主要设计用于〜(26)Al离子,将大大提高Lund AMS设施的实验潜力。通过使用90°球形静电分析仪和90°磁性分析仪,可以获得高质量的能量和质量分辨率。注射器配备了带有球形离子发生器的高强度溅射源。一种用于接受度计算的新分析技术以及基于PC的计算方法已用于新注射器的离子光学系统的设计中。与我们的旧式进样器系统相比,旧式进样器系统具有仅15°弯曲角的电磁分析仪,新系统的分辨率提高了十倍以上。新系统的光束光学系统也经过了更好的设计,以符合加速器的要求。这样,针对我们AMS程序中感兴趣的不同离子,从离子源到检测器的离子传输量就增加了。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号