...
首页> 外文期刊>IEEE Transactions on Power Systems >Control of an HVdc Link Connecting a Wind Farm to the Grid for Fault Ride-Through Enhancement
【24h】

Control of an HVdc Link Connecting a Wind Farm to the Grid for Fault Ride-Through Enhancement

机译:控制将风电场连接到电网的HVdc链路以提高故障穿越能力

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

This paper studies the issue of the fault ride-through capability of a wind farm of induction generators, which is connected to an AC grid through an HVDC link based on voltage sourced converters (VSCs). National grid codes require that wind turbines should stay connected to the power system during and after short-circuit faults. In the latest literature, when the technology of HVdc based on VSCs is used to connect a wind farm to the power system, the blocking of the VSCs valves for a predefined short time interval is applied, in order to avoid the overcurrents and the tripping of the wind turbines. This paper proposes a control strategy that blocks the converters for a time interval which depends on the severity of the fault and takes special actions in order to alleviate the post-fault disturbances. In this way, the overcurrents are limited, the wind turbines manage to remain connected, and the AC voltage recovers quickly.
机译:本文研究了感应发电机风场的故障穿越能力问题,感应风场通过基于电压源转换器(VSC)的HVDC链路连接到交流电网。国家电网法规要求在发生短路故障期间和之后,风力涡轮机应保持与电力系统的连接。在最新文献中,当使用基于VSC的HVdc技术将风电场连接到电力系统时,会在预定的短时间间隔内对VSC阀门进行阻塞,以避免过电流和电网跳闸。风力涡轮机。本文提出了一种控制策略,该控制策略在一定的时间间隔内阻塞转换器,该时间间隔取决于故障的严重程度并采取特殊措施以减轻故障后的干扰。这样,可以限制过电流,风力涡轮机设法保持连接,并且交流电压迅速恢复。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号