摘要

The traditional laboratory experiment on three-phase transformer connections consists of a qualitative observation of current and phase voltage waveforms by means of an oscilloscope, with emphasis placed on the dominant third harmonic component. Some recorded waveshapes, however, cannot be explained in simple terms without considering other harmonic components and the quality of power supply. This paper outlines an improved lecture/experiment that quantitatively analyzes the waveforms of various transformer connections under steady-state no-load conditions while taking into account the nonideal voltage supply. The experimental data obtained with the aid of a harmonic analyzer are then compared to the qualitative predictions and the discrepancies are discussed.
机译:传统的三相变压器连接实验室实验包括通过示波器对电流和相电压波形进行定性观察,重点放在主要的三次谐波分量上。但是,如果不考虑其他谐波分量和电源质量,就不能用简单的术语来解释某些记录的波形。本文概述了一种改进的讲座/实验,它在考虑到非理想电源的情况下,定量分析了稳态空载条件下各种变压器连接的波形。然后将借助谐波分析仪获得的实验数据与定性预测进行比较,并讨论差异。