A fuzzy dissolved gas analysis method for the diagnosis of multipleincipient faults in a transformer

机译:用于变压器多发故障的模糊溶解气体分析方法

获取原文
获取原文并翻译 | 示例
           

摘要

Dissolved gas analysis (DGA) of transformer oil has been one ofnthe most useful techniques to detect the incipient faults. Variousnmethods, such as the IEC codes, have been developed to interpret DGAnresults directly obtained from a chromatographer. Although these methodsnare widely used in the world, they sometimes fail to diagnose,nespecially when more than one fault exists in a transformer. This papernpresents a fuzzy logic technique which can diagnose multiple faults in antransformer and quantitatively indicates the likelihood/severity of eachnfault. Insulation deterioration at each fault location can then benmonitored closely according to its trend, which is important for antransformer in critical situation. Tests using this technique on annumber of transformers have given promising results
机译:变压器油中的溶解气体分析(DGA)已成为检测初期故障的最有用的技术之一。已经开发出各种方法(例如IEC编码)来解释直接从色谱仪获得的DGAnresults。尽管这些方法在世界范围内已广泛使用,但有时有时无法诊断,尤其是当变压器中存在多个故障时。本文提出了一种模糊逻辑技术,该技术可以诊断变压器中的多个故障并定量指示每个故障的可能性/严重性。然后可以根据其趋势密切监测每个故障位置的绝缘劣化,这对于处于紧急情况下的变压器而言非常重要。使用此技术在许多变压器上进行的测试均给出了可喜的结果