This paper presents results of an analytical core loss calculationnmethod developed for single phase and five limb three phase core types.nShown are calculation results of flux distributions, flux densitynwaveshapes, spatial flux density curves and loss distributions in coresnother than the 3 phase-3 limb core. The analytical results show that thenflux distribution is essentially uniform in the single-phase 2 limb andn3 limb cores. The flux waveforms are also shown to be essentiallynsinusoidal in different regions of the core. However, for thensingle-phase 4 limb core and the three-phase 5 limb core, the fluxndistribution is nonuniform and flux waves are very distorted. Thencalculated values of core losses were, generally, in excellent agreementnwith tested core losses of actual commercial transformers. The resultsnon the very large 4 and 5 limb cores show that the production complexitynof these cores cause a slightly higher tested core loss which needs tonbe included in the development of the core loss calculation for thesencores
机译:本文介绍了针对单相和五肢三相铁心类型开发的分析铁心损耗计算方法的结果.n显示的是除三相三肢铁心以外的铁心中通量分布,通量密度n波形,空间通量密度曲线和损耗分布的计算结果。分析结果表明,单相2肢和n3肢核中的通量分布基本均匀。磁通波形在磁芯的不同区域也显示为基本正弦波。但是,对于单相四臂铁心和三相五臂铁心,通量分布不均匀,通量波非常畸变。然后,计算得出的铁心损耗值通常与实际商用变压器的测试铁心损耗非常吻合。非大型4芯和5芯铁心的结果表明,这些铁心的生产复杂性导致测试的铁心损耗略高,需要将其纳入sencore的铁心损耗计算开发中

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号