首页> 外文期刊>IEEE Transactions on Power Delivery >A novel procedure based on lab tests for predicting single-phase power electronics-based loads harmonic impact on distribution networks
【24h】

A novel procedure based on lab tests for predicting single-phase power electronics-based loads harmonic impact on distribution networks

机译:一种基于实验室测试的新颖程序,用于预测基于单相电力电子的负载谐波对配电网络的影响

获取原文
获取原文并翻译 | 示例
           

摘要

The paper illustrates the results of an experimentally based procedure aimed at estimating the mutual influence between single-phase nonlinear (NL) loads and the upstream supply system. The procedure provides harmonic monitoring of a nonlinear appliance supplied from a low-voltage (LV) distribution network outlet. The appliance is connected to the outlet through a variable impedance whose components can be adequately varied in order to artificially reproduce upstream system and load variations. The monitoring results allowed "ONE"? to define both current and voltage harmonic spectrum variations versus some parameters that have been found as most influencing the attenuation effects. From the monitoring activity performed on personal computers, some curves have been determined that can be used for a parametrical estimation of: a) the attenuation effect of voltage distortion on net harmonic current drawn by the NL appliance; and b) the impact of the NL appliance on voltage distortion at the point of common coupling in terms of voltage total harmonic distortion (VTHD) increase.
机译:本文说明了基于实验的过程的结果,该过程旨在估计单相非线性(NL)负载与上游供电系统之间的相互影响。该程序提供对从低压(LV)配电网络插座提供的非线性设备的谐波监控。该设备通过可变阻抗连接到插座,其阻抗可以适当改变,以便人为地复制上游系统和负载变化。监视结果允许“一个”吗?定义电流和电压谐波频谱的变化以及某些参数,这些参数是影响衰减效果最大的参数。根据在个人计算机上执行的监视活动,已确定了一些曲线,可用于以下参数的估计:a)电压失真对NL设备汲取的净谐波电流的衰减影响; b)在电压耦合总谐波失真(VTHD)增加方面,NL设备在公共耦合点对电压失真的影响。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号