首页> 外文期刊>Power Delivery, IEEE Transactions on >Sensitivity of Steady-State Temperatures of SF$_{6}$ Gas-Cooled-Insulated Power Transformers to Selected Parameters
【24h】

Sensitivity of Steady-State Temperatures of SF$_{6}$ Gas-Cooled-Insulated Power Transformers to Selected Parameters

机译:SF $ _ {6} $气冷式绝缘电力变压器稳态温度对所选参数的敏感性

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

The effects of cooling methods, gas pressure, gas velocity, electrical loading, and environmental parameters on the steady-state temperature distribution of SF6 gas-cooled-insulated power transformers are investigated by using the finite-element method. The contributions of convection and radiation to the total heat-transfer rate inside and outside the transformer are included. The results provide useful sensitivity information which can be accessed and manipulated by the transformer designers or operators. This sensitivity information significantly reduces the analysis and computations via identifying the important parameters that most affect the temperature distribution in this type of transformer.
机译:采用有限元方法研究了冷却方式,气体压力,气体速度,电负荷和环境参数对SF6气冷式绝缘电力变压器稳态温度分布的影响。对流和辐射对变压器内部和外部总传热率的影响也包括在内。结果提供了有用的灵敏度信息,可以由变压器设计人员或操作人员进行访问和操作。通过识别对这种类型的变压器的温度分布影响最大的重要参数,此敏感度信息可大大减少分析和计算。