首页> 外文期刊>Power Delivery, IEEE Transactions on >Effect of the Formation of the Dry Zone Around Underground Power Cables on Their Ratings
【24h】

Effect of the Formation of the Dry Zone Around Underground Power Cables on Their Ratings

机译:地下电缆周围干区的形成对其额定值的影响

获取原文
获取原文并翻译 | 示例
           

摘要

Many factors affect the loading of the underground power cables, such as ambient temperature, depth of laying of cable, number of parallel circuits of cable, and thermal resistivity of the surrounding soil. One important factor, usually ignored, is the formation of dry zones around the underground power cables. Dry zones are usually formed around underground power cables under loading conditions due to the migration of moisture within the soil. In this paper, the effect of the formation of the dry zone on the ampacity of underground power cables is investigated. The derating factor for the formation of dry zones around underground power cables is suggested and calculated for different types of natural backfill soil. IEC 60287-1-3 is taken as a reference. Experimental work was conducted to study the phenomena of the dry zone as related to different types of soils.
机译:许多因素都会影响地下电缆的负载,例如环境温度,电缆的铺设深度,电缆的并联电路数以及周围土壤的热阻。一个通常被忽略的重要因素是在地下电缆周围形成干燥区域。由于水分在土壤中的迁移,通常在负载条件下在地下电缆周围形成干燥区域。本文研究了干燥区的形成对地下电缆载流量的影响。建议并针对不同类型的天然回填土计算出了地下电缆周围干燥区域形成的降额因数。以IEC 60287-1-3为参考。进行了实验工作以研究与不同类型土壤相关的干旱区现象。