This paper deals with the comparison between the overall whole-of-life costs of overhead lines (OHL) and those of underground insulated cables (UGC). Almost all the investigations published so far, when analyzing maintainability issues, take into account only the costs of planned/periodical maintenance; here, a method for assessing also the expenses sustained for repair after random failures is proposed. The number of random failure events for each kind of component over the entire service life of a transmission line can only be predicted on a probabilistic basis: its expected value is estimated by making use of the relevant mean failure rates from recent statistical surveys. The entire procedure is shown by carrying out a particular case study as an example; the break-even point between the OHL-UGC overall costs, corresponding to a typical rural land Italian market value ${rm w}_{rm x}={hbox {26.9}} {rm Euros/m}^{2}$ , is identified. Nonetheless, the method may be widely applied to any type of OHL–UGC comparison.
机译:本文旨在比较架空线(OHL)和地下绝缘电缆(UGC)的整个生命周期成本。到目前为止,在分析可维护性问题时,几乎所有已发表的调查报告都仅考虑计划/定期维护的成本;在此,提出了一种还评估随机故障后维修费用的方法。只能在概率的基础上预测传输线整个使用寿命中每种组件的随机故障事件的数量:其预期值是根据最近的统计调查得出的相关平均故障率来估算的。整个过程以一个特定的案例研究为例来说明; OHL-UGC总成本之间的收支平衡点,对应于典型的农村土地意大利市场价值$ {rm w} _ {rm x} = {hbox {26.9}} {rm Euros / m} ^ {2} $被识别。但是,该方法可能广泛应用于任何类型的OHL-UGC比较。

著录项

相似文献

  • 外文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号