Interference From UHVDC Power Line on Geomagnetic Observation and its Correction

机译:特高压直流输电线路对地磁观测的干扰及其校正

获取原文
获取原文并翻译 | 示例
           

摘要

A correction system for geomagnetic observation against interference from the UHVDC power line is developed. The system could offer accurate calculation of interference value and, thus, realize the real-time correction in the Z component observation of the geomagnetic field. Based on the 3-D current magnetic-field calculation model of the dc power line, in which the towers as points and the tower spans as line segments, the calculation equation of the pace current magnetic-field vector projected on the direction of the Z component vector is acquired to calculate the interference value from the power line. Using Microsoft Visual Basic 6.0, the system receives the values of imbalance current on the UHVDC power line and geomagnetic Z component observation through the PC serial port. Consequently the real-time calculation of interference value on the Z component from the power line is realized. Then, the actual geomagnetic observation curve is acquired. During the live debugging period of $pm $800~kV Xiangjiaba—Shanghai UHVDC power line, the high accuracy of the correction system is verified by the joint experiment of the current observation in converter stations and the indoor/infield geomagnetic observation.
机译:开发了一种针对地磁观测的超高压直流输电线路干扰校正系统。该系统可以提供精确的干扰值计算,从而实现对地磁场Z分量观测的实时校正。基于以塔为点,塔跨为线段的直流电源线的3-D电流磁场计算模型,步速电流磁场矢量的计算方程式投影在Z方向上获取分量矢量以计算来自电力线的干扰值。使用Microsoft Visual Basic 6.0,系统通过PC串行端口接收UHVDC电源线上的不平衡电流值和地磁Z分量观测值。因此,实现了来自电力线的Z分量的干扰值的实时计算。然后,获取实际的地磁观测曲线。在$ pm $ 800〜kV向家坝—上海特高压直流输电线路的现场调试期间,通过换流站电流观测与室内/场内地磁观测的联合实验,验证了校正系统的高精度。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号