As a key element of a power system, a circuit breaker (CB) requires regular maintenance. Intelligent online condition assessment is increasingly becoming a requirement for key items of power plants, including CBs. The interruption chamber, as the most critical part of the CBs, plays an important role in the proper operation of CBs. Online assessment of this part is difficult from a technical perspective due to the high noise level and presence of a transient recovery voltage. This paper proposes a set up for the online measurement of the CB arc voltage during trip/close operations. In addition, a method has been proposed to evaluate the remaining useful lifetime of the interruption chamber based on the measured arc voltage and current. The setup and the proposed approach are verified experimentally.
机译:断路器(CB)作为电力系统的关键要素,需要定期维护。智能在线状态评估越来越成为包括CB在内的电厂关键项目的要求。断路器室是断路器的最关键部分,在断路器的正常运行中起着重要作用。从技术角度来看,由于高噪声水平和瞬态恢复电压的存在,很难在线评估该部分。本文提出了一种在跳闸/合闸操作期间在线测量CB电弧电压的装置。另外,已经提出了一种基于测得的电弧电压和电流来评估中断室的剩余使用寿命的方法。该设置和提出的方法已通过实验验证。