This paper demonstrates the presence of spurious power losses or generation in the Arm Equivalent Model (AEM) of Modular Multilevel Converters. Such power losses can occur if model equations are not solved simultaneously with surrounding power circuit equations, which is the case when the AEM is implemented using control system blocks in electromagnetic transient simulation software. Depending on operating conditions and simulation parameters, these additional losses can represent a significant part of the total converter station losses or even surpass them, thus making simulation results inaccurate. Analytical demonstration of the losses is presented, and several models that eliminate the losses are proposed. Based on simulation studies, only the variable resistance model and equivalent voltage source model can give accurate simulation results without significantly increasing simulation time and generating or consuming spurious power.
机译:本文演示了模块化多电平转换器的Arm等效模型(AEM)中存在虚假功率损耗或产生的情况。如果模型方程式不能与周围的电源电路方程式同时求解,则可能会发生这种功率损耗,这是使用电磁瞬态仿真软件中的控制系统模块实现AEM时的情况。根据运行条件和仿真参数,这些额外的损耗可能占换流站总损耗的很大一部分,甚至超过损耗,从而使仿真结果不准确。给出了损失的分析论证,并提出了几种消除损失的模型。根据仿真研究,只有可变电阻模型和等效电压源模型才能给出准确的仿真结果,而不会显着增加仿真时间以及产生或消耗虚假功率。