Primary Investigation into the Laser Triggering Multi-Gap Multi-Channel Gas Switch in a Single Test Module Facility

机译:在单个测试模块中对激光触发多间隙多通道气体开关进行的初步研究

获取原文
获取原文并翻译 | 示例
           

摘要

A high precision laser trigger system is built up in the single test module of Primary Test Stand (PTS) facility. A fourth harmonic, with a wavelength A of 266 nm, Q-switched Nd:YAG laser was used to trigger the 5 MV multi-gap multi-channel gas switch which was filled with high pressure SF_6-N_2 mixture gas. The maximum deviation and the standard deviation in the jitter time of the trigger system is ± 0.7 ns and 0.3 ns respectively. The maximum deviation and the standard deviation in the jitter time for the multi-gap multi-channel laser triggering switch is ± 2.4 ns and 1.5 ns respectively. The curve of switch delay-time versus laser energy is obtained, which is helpful for the choice of fitting laser energy. The successful test with two lasers indicated that the design of using twenty-four lasers to trigger twenty-four switches respectively is feasible in "PTS".
机译:在主测试台(PTS)设备的单个测试模块中建立了高精度的激光触发系统。 Q开关Nd:YAG激光器使用波长为266 nm的四次谐波来触发5 MV多间隙多通道气体开关,该开关充满了高压SF_6-N_2混合气体。触发系统抖动时间的最大偏差和标准偏差分别为±0.7 ns和0.3 ns。多间隙多通道激光触发开关的抖动时间的最大偏差和标准偏差分别为±2.4 ns和1.5 ns。获得了开关延迟时间与激光能量的关系曲线,这有助于选择合适的激光能量。使用两个激光器的成功测试表明,在“ PTS”中使用二十四个激光器分别触发二十四个开关的设计是可行的。