A calibrating device for the Rogowski coil is developed, which can be used to calibrate the Rogowski coil having a partial response time within tens of nanoseconds. Its key component is a step current generator, which can generate the output with a rise time of less than 2 ns and a duration of larger than 300 ns. The step current generator is composed by a pulse forming line (PFL) and a pulse transmission line (PTL). A TEM (transverse electromagnetic mode) coaxial measurement unit is used as PTL, and the coil to be calibrated and the referenced standard Rogowski coil can be fixed in the unit. The effect of the dimensions of the TEM unit is discussed theoretically as well as experimentally.
机译:开发了用于Rogowski线圈的校准设备,该设备可用于校准具有数十纳秒以内部分响应时间的Rogowski线圈。它的关键组件是步进电流发生器,它可以产生上升时间小于2 ns,持续时间大于300 ns的输出。步进电流发生器由脉冲形成线(PFL)和脉冲传输线(PTL)组成。 TEM(横向电磁模式)同轴测量单元用作PTL,可以将要校准的线圈和参考的标准Rogowski线圈固定在该单元中。在理论上和实验上都讨论了TEM单元尺寸的影响。