Langmuir probes operating in the electron saturation current mode were used to detect the time of the arrival of the cathode sheath at the probe position. The probe current was measured just before and after current zero (CZ) followed the transient recovery voltage in a gap with copper electrodes. Probe measurements were accompanied with the detection of the postarc currents. Basic plasma parameters such as electron temperature and density were measured in the vicinity of the arcing gap. The data set allowed us to reconstruct the sheath dynamics after CZ.
机译:使用以电子饱和电流模式运行的Langmuir探针来检测阴极鞘到达探针位置的时间。在电流零(CZ)之前和之后的瞬态恢复电压与铜电极之间的间隙中测量探针电流。探针测量伴随着弧后电流的检测。在电弧隙附近测量基本的等离子体参数,例如电子温度和密度。数据集使我们能够重建CZ之后的鞘层动力学。