...
首页> 外文期刊>Plasma Science, IEEE Transactions on >Internal Charging Measurements in Medium Earth Orbit Using the SURF Sensor: 2005–2014
【24h】

Internal Charging Measurements in Medium Earth Orbit Using the SURF Sensor: 2005–2014

机译:使用SURF传感器在中地球轨道上的内部充电测量:2005–2014年

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

The SURF internal charging monitor that measures deposited currents in three shielded aluminum plates is one of the sensors within the Merlin radiation monitoring instrument launched on Giove-A in December 2005 into a 23300-km circular 56° inclination medium earth orbit. The instrument has now completed 8.5 years in orbit despite being originally intended for a two-year operational life. Here, we report on the instrument’s health, provide further recent data, and review the overall results in terms of their engineering significance. It is concluded that the instrument remains in good health, with no significant deterioration, and a near continuous data set from December 2005 to April 2014 is now available. The maximum plate currents to date were recorded over the period April 6–8, 2010, during a significant outer electron belt enhancement (also observed by Geostationary Operational Environmental Satellite (GOES)-12 in geostationary orbit), which persisted for several days. From April 7 to April 9, 2010, the current in the most shielded plate (1.0-mm thickness with 1.5-mm shielding) exceeded the widely used 0.1-pA cm safety threshold for internal charging (the only days in the mission where this occurred), and on these days, it also exceeded the reasonable worst case current predications given by the DICTAT internal charging tool (the other plate currents remained within DICTAT predictions). The 0.02-pA cm safety threshold used in European ECSS charging standards for dielectrics below 25 °C has been exceeded on a far larger number of days; for example, in the most shielded plate, it has been exceeded on 55 days (8% of the total).
机译:SURF内部充电监测器可测量三个屏蔽铝板上的沉积电流,它是Merlin辐射监测仪器中的传感器之一,该仪器于2005年12月在Giove-A上发射,进入了23300公里的圆形56°倾角中等地球轨道。尽管该仪器原本打算使用两年,但目前已经完成了8.5年的在轨运行。在这里,我们将报告仪器的健康状况,提供进一步的最新数据,并就其工程意义评估总体结果。结论是该仪器保持良好的健康状态,没有明显的恶化,现在可以得到从2005年12月到2014年4月几乎连续的数据集。迄今为止,记录的最大板块电流是在2010年4月6日至8日期间,在显着的外电子带增强期间(也由对地静止轨道上的对地静止运行环境卫星(GOES)-12观测到),该持续了几天。从2010年4月7日至4月9日,屏蔽程度最高的板(厚度为1.0毫米,屏蔽层为1.5毫米)中的电流超过了内部充电安全使用的0.1 pA cm安全阈值(任务中仅有的几天) ),并且在最近几天,它也超过了DICTAT内部充电工具给出的合理的最坏情况下的电流预测(其他极板电流仍在DICTAT预测之内)。欧洲ECSS充电标准中针对25°C以下的电介质使用的0.02 pA cm安全阈值已远远超过了很多天;例如,在最屏蔽的板中,超过了55天(占总数的8%)。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号