The project demonstrated the ability of multipath ultrasonic meters to detect changes in the condition of the upstream pipe caused by accumulated material. A ratio of meter path velocities was found to be a good indicator of the condition of the upstream pipe. The path velocity ratio is a parameter that is commonly available in the diagnostic software for ultrasonic meters.rnThe results also indicated that the meter accuracy was relatively insensitive to the condition of the upstream pipe up to the maximum coating thickness of approximately 0.05 inches tested here. The maximum deviation of the flow measurement over the range of coatings applied during these tests was approximately 0.2% for both meter types. However, the maximum deviation occurred at different coating levels for the different meters.
机译:该项目证明了多径超声波测量仪能够检测由累积的材料引起的上游管道状况的变化。发现米路径速度的比率可以很好地指示上游管道的状况。流速比是超声波流量计的诊断软件中通常可用的参数。结果还表明,流量计的精度对上游管道的状况相对不敏感,直到此处测试的最大涂层厚度约为0.05英寸。对于两种仪表,在这些测试过程中所施加的涂层范围内,流量测量值的最大偏差约为0.2%。但是,对于不同的仪表,最大偏差发生在不同的涂层水平上。

著录项

  • 来源
    《Pipeline & gas journal》 |2009年第7期|29-32|共4页
  • 作者

    Terrence A. Grimley;

  • 作者单位

    Southwest Research Institute, San Antonio, TX;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);美国《生物学医学文摘》(MEDLINE);美国《化学文摘》(CA);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

  • 入库时间 2022-08-18 01:17:59

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号