首页> 外文期刊>Photodiagnosis and Photodynamic Therapy >Disinfection of acrylic denture resin polymer with Rose Bengal, Methylene blue and Porphyrin derivative in photodynamic therapy
【24h】

Disinfection of acrylic denture resin polymer with Rose Bengal, Methylene blue and Porphyrin derivative in photodynamic therapy

机译:丙烯酸义齿树脂聚合物对光动力疗法中玫瑰孟加拉,亚甲基蓝和卟啉衍生物的消毒

获取原文
获取原文并翻译 | 示例
           

摘要

Aim: The study aimed to assess the effect of in-vitro chlorhexidine and antimicrobial photodynamic therapy (aPDT) disinfection protocols against acrylic resin specimens colonized with S. mutans, S. aureus, E. coli, and C. albicans. Material and Methods: Reference strains of S. mutans, S. aureus, E. coli, and C. albicans were tested. Sixteen blocks of acrylic specimens were prepared by heat-cure acrylic resin and contaminated by in-vitro biofilm growth. Specimens in group 1, group 2 and group 3 were treated with Rose Bengal (RB), methylene blue (MB) 500 mg/L and porphyrin derivative (PD) 5 ml respectively, for the sensitization of biofilms. All photosensitizers (PS) were activated by LED at different wavelength. CHX was prepared in sterile distilled water and applied for 60 s. Each contaminated specimen was sprayed on all its surfaces with the aforementioned photosensitizers and control CHX. One-way analysis of variance (ANOVA) model was used to test the effect of the treatments and Tukey multiple comparison tests to compare means OF CFU/mL (log10) for exposed E. coli, C. albicans, S aureus, and S. mutans Results: Specimens treated with 0.12% CHX (control) demonstrated a significant reduction in CFU/mL (log10) for exposed E. coli; 2.04 +/- 0.07 CFU/mL, C. albicans; 2.09 +/- 0.85 CFU/mL, S aureus; 3.04 +/- 0.11 CFU/mL, and S. mutans; 2.54 +/- 0.91 CFU/mL. The intragroup comparison revealed E.coli did not exhibit a decrease in reduction CFU/mL (log10) when acrylic resin irradiated with RB 5 mu m. Whereas, CFU/mL (log10) values of S.aureus; 3.62 +/- 0.68 and S.mutans; 3.41 +/- 0.13 plummeted (p0.05). Intergroup comparison showed E.coli values to display comparable reduction when disinfected with MB 500 mg/L and 0.12% CHX; 3.16 +/- 0.34 and 2.04 +/- 0.07 CFU/mL (log10) (p0.05). Conclusion: Photosensitizers (RB, MB, PD) are selective in reducing bacterial count on acrylic resin blocks. CHX was found to be effective against all bacteria E.coli, C.albicans, S.aureus, and S.mutans at a concentration of 0.12%.
机译:目的:该研究旨在评估体外氯化物和抗微生物动力治疗(APDT)消毒方案对与S.Ureans,Aureus,大肠杆菌和C. albicans殖民的丙烯酸树脂标本对丙烯酸树脂标本的影响。材料和方法:测试了S.ureans的参考菌株,S.UUREUS,大肠杆菌和C. albicans进行了测试。通过热固化丙烯酸树脂制备十六块丙烯醛样品,并通过体外生物膜生长污染。第1组,第2组和第3组分别用玫瑰叶(Rb),亚甲基蓝(Mb)500mg / L和卟啉衍生物(Pd)5mL分别用玫瑰孟加拉(Rb)处理,用于敏化生物膜的敏化。所有光敏剂(PS)都是通过不同波长的LED激活的。 CHX在无菌蒸馏水中制备并施加60秒。用上述光敏剂和对照CHX喷洒每个污染的样品并用上述光敏剂喷洒。方差的单向分析(ANOVA)模型用于测试治疗和Tukey多种比较试验的效果,以比较CFU / ml(LOG10)的细化大肠杆菌,C. albicans,S金黄色葡萄球菌和S. Mutans结果:用0.12%CHX(对照)处理的试样证明了暴露的大肠杆菌的CFU / mL(LOM10)的显着降低; 2.04 +/- 0.07 cfu / ml,c. albicans; 2.09 +/- 0.85 CFU / ml,金黄色葡萄球菌; 3.04 +/- 0.11 cfu / ml和s. mutans; 2.54 +/- 0.91 CFU / ml。当用RB5μm照射的丙烯酸树脂时,Intragrous的比较显示出的E.COLI并未表现出还原CFU / mL(log10)的降低。而S.aureus的CFU / ml(log10)值; 3.62 +/- 0.68和s.mutans; 3.41 +/- 0.13暴跌(P <0.05)。依群比较显示了大肠杆菌值,以显示用MB 500 mg / L和0.12%CHX消毒时的可比减少; 3.16 +/- 0.34和2.04 +/- 0.07 CFU / mL(LOG10)(P <0.05)。结论:光敏剂(RB,MB,PD)在减少丙烯酸树脂块上的细菌计数方面是选择性的。发现CHX对所有细菌E.coli,C.albicans,S.aureus和S.mutans的浓度有效。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号