首页> 外文期刊>Osaka City Medical Journal >Is Ulnar Variance Suitable for a Parameter of Colles' Fracture Pre-Operatively?
【24h】

Is Ulnar Variance Suitable for a Parameter of Colles' Fracture Pre-Operatively?

机译:尺骨方差术前是否适合于Colles骨折的参数?

获取原文
获取原文并翻译 | 示例
       

摘要

Background To evaluate ulnar variance (UV) as a parameter for Colles' fracture as a measure of the true length of the distal radius pre-operatively, we measured UV pre-operatively in 20 patients with Colles' fractures being treated surgically using the method of perpendiculars. Because the distal fragment is by definition dorsi-flexed, the dorsal edge of the most distal part of the radius is seen proximally and the volar edge of it is seen distally on true postero-anterior x-ray of the wrist. Methods We measured three different UVs in x-rays. UVd is the distance from the dorsal edge of the distal radius to the distal end of the ulnar head. UVv is the distance from the volar edge of the distal radius to the distal end of the ulnar head. We calculated UVc using lateral x-ray of the wrist at the midpoint of the lunate fossa to describe the true length of the distal radius. We compared UVd with UVv or UVc in 20 patients as well as in 11 patients who had dorsal tilt over 15 degrees. Results UVv was -3.8±2.5 mm (average+SD). UVd was 2.2±2.4 mm. UVc was 1.7+2.2 mm. Statistically, there was a significant difference between UVv and UVd (p<0.0001). There was no statistically significant difference between UVd and UVc. However, in 11 cases with dorsal tilt over 15 degrees, UVd was 2.2±2.8 mm and UVc was 1.1±2.7 mm. There was a statistically significant difference between both groups (p=0.003). Conclusions The length of the distal radius can be described by measuring UVd pre-operatively in Colles' fracture patient in general. However, the true length of the distal radius can not be described by measuring UVd pre-operatively in cases with marked dorsi-flexion of the distal fragment.
机译:背景为了评估尺骨方差(UV)作为Colles骨折的参数,以术前测量远端radius骨的真实长度,我们对20例经手术治疗的Colles骨折的患者进行了术前测量,方法是垂直线。根据定义,由于远端片段是背屈的,因此在腕部的真实后前X线片上,可以从近端看到radius骨最远端部分的背侧边缘,而从远端可以看到vol骨的掌侧边缘。方法我们在X射线中测量了三种不同的紫外线。 UVd是从radius骨远端边缘到尺骨远端的距离。 UVv是从radius骨远端的掌骨边缘到尺骨远端的距离。我们使用月牙窝中点处的腕部侧向X射线计算UVc,以描述远端radius骨的真实长度。我们比较了20位患者以及11位背斜超过15度的患者中的UVd与UVv或UVc。结果UVv为-3.8±2.5mm(平均值+ SD)。 UVd为2.2±2.4mm。 UVc为1.7±2.2mm。统计上,UVv和UVd之间存在显着差异(p <0.0001)。 UVd和UVc之间没有统计学上的显着差异。然而,在11例背斜超过15度的病例中,UVd为2.2±2.8mm,UVc为1.1±2.7mm。两组之间有统计学显着性差异(p = 0.003)。结论一般而言,可通过术前测量Colles骨折患者的UVd来描述described骨远端的长度。但是,在远端碎片明显背屈的情况下,无法通过术前测量UVd来描述远端radius骨的真实长度。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号