首页> 外文期刊>Optics and Lasers in Engineering >Identification and correction of microlens array rotation error in plenoptic imaging systems
【24h】

Identification and correction of microlens array rotation error in plenoptic imaging systems

机译:集水成像系统中微透镜阵列旋转误差的识别和校正

获取原文
获取原文并翻译 | 示例
           

摘要

Plenoptic imaging systems can acquire spatio-angular information of light rays, allowing complex scene measurements with a single exposure. The measurement accuracy is significantly affected by the orientation parameters of internal components in the system, especially the rotation error between the microlens array (MLA) and the image sensor. In this paper, we formulate an MLA rotation error model to derive the transformations between the error point and its ideal point of ray projection. Furthermore, we present a method for identifying and correcting the rotation error, including error angle estimation, raw image rotation, and refocused image reverse rotation. Through simulation experiments, the imaging characteristics of the MLA rotation error are analyzed and the performance of the proposed model and method are verified. The results demonstrate that the integral distribution of raw image distortion caused by the error is centrosymmetric. In the error range of 0.1-1.0 degrees, the mean square error (MSE) and structural similarity index metric (SSIM) of the corrected refocused images are improved to 0.2146-3.8190 and 0.9986-0.9999, respectively.
机译:聚集体成像系统可以获取光线的时空信息,允许单次曝光的复杂场景测量。测量精度受系统中内部组件的取向参数的显着影响,尤其是微透镜阵列(MLA)和图像传感器之间的旋转误差。在本文中,我们制定了MLA旋转误差模型,以导出误差点与其理想点之间的变换。此外,我们介绍一种用于识别和校正旋转误差的方法,包括误差角估计,原始图像旋转和重新分叉图像反向旋转。通过仿真实验,分析了MLA旋转误差的成像特性,验证了所提出的模型和方法的性能。结果表明,由误差引起的原始图像失真的积分分布是CentroSymmetric。在0.1-1.0度的误差范围内,校正的重新聚焦图像的平均误差(MSE)和结构相似性指数度量(SSIM)分别改善为0.2146-3.8190和0.9986-0.9999。

著录项

  • 来源
    《Optics and Lasers in Engineering》 |2019年第10期|156-168|共13页
  • 作者单位

    Harbin Inst Technol Sch Energy Sci & Engn 92 West Dazhi St Harbin 150001 Heilongjiang Peoples R China;

    Harbin Inst Technol Sch Energy Sci & Engn 92 West Dazhi St Harbin 150001 Heilongjiang Peoples R China|Harbin Inst Technol Minist Ind & Informat Technol Key Lab Aerosp Thermophys 92 West Dazhi St Harbin 150001 Heilongjiang Peoples R China;

    Harbin Inst Technol Sch Energy Sci & Engn 92 West Dazhi St Harbin 150001 Heilongjiang Peoples R China;

    Harbin Inst Technol Sch Energy Sci & Engn 92 West Dazhi St Harbin 150001 Heilongjiang Peoples R China|Harbin Inst Technol Minist Ind & Informat Technol Key Lab Aerosp Thermophys 92 West Dazhi St Harbin 150001 Heilongjiang Peoples R China;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    Calibration; Rotation error; Light field; Microlens array; Plenoptic imaging systems;

    机译:校准;旋转误差;光场;微透镜阵列;压力学成像系统;