In the strain field measurements, especially in large strain field measurements, the correlation coefficient values obtained by the digital speckle correlation method are usually very low due to the relative pixel movement of the subset. The measuring error, therefore, is increased. A primary method, that is called compensation algorithm, is introduced for improving the correlation coefficient. A flow scheme with the compensation algorithm of our software is developed and some improved techniques for reducing the calculation time and error are discussed in the paper. After obtaining a set of displacement data with high correlation coefficient, a de-noise wavelet processing is adopted. It is obvious that the measuring accuracy of the strain field is better then before. A strain field of testing experiment is performed with this compensation technique. The correlation coefficients can increase from 0.70 to 0.99, which will be of much benefit for the improvements of the measuring accuracy.
机译:在应变场测量中,特别是在大应变场测量中,由于子集的相对像素运动,通过数字散斑相关方法获得的相关系数值通常非常低。因此,测量误差增加。引入了一种主要的方法,称为补偿算法,以提高相关系数。开发了一种使用我们软件补偿算法的流方案,并讨论了减少计算时间和减少误差的一些改进技术。在获得一组具有高相关系数的位移数据之后,采用去噪小波处理。显然,应变场的测量精度比以前好。利用该补偿技术进行了试验实验的应变场。相关系数可以从0.70增加到0.99,这对于提高测量精度将大有裨益。