【24h】

Q & A

机译:问与答

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

I need a power supply that puts out (max.) 60V at 13 amps. Ripple is not too important, as long as it is no more than 0.5V or 1V. I don't want to use expensive transformers, though. Is there a switching mode that can run off house current? Both these requests are similar enough to use the same basic circuit. The power output at 20 volts, 40 amps is 800 watts and the power at 60 volts, 13 amps is 780 watts. The power input will be higher due to losses, so plan on 1,000 watts input (8.3 amps at 120 VAC). Since the big deal for me is the transformer design, I will do that first. I am using the Magnetics, Inc., manual for ferrite cores.
机译:我需要一个在13 A时输出(最大)60V的电源。纹波不是太重要,只要不超过0.5V或1V。不过,我不想使用昂贵的变压器。有没有可以消耗室内电流的开关模式?这两个请求足够相似,可以使用相同的基本电路。 20伏特40安培时的功率输出为800瓦,而60伏特13安培时的功率输出为780瓦。由于损耗,电源输入会更高,因此请计划使用1,000瓦的输入(120 VAC时为8.3安培)。由于对我来说重要的是变压器设计,因此我将首先进行设计。我正在使用Magnetics,Inc.的铁氧体磁芯手册。