首页> 外文期刊>Nuclear Instruments & Methods in Physics Research. B, Beam Interactions with Materials and Atoms >Neutron energy spectrum measurement using an NE213 scintillator at CHARM
【24h】

Neutron energy spectrum measurement using an NE213 scintillator at CHARM

机译:在CHARM使用NE213闪烁体测量中子能谱

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

To establish a methodology for neutron spectrum measurement at the CERN High energy AcceleRator Mixed field facility (CHARM), neutron spectra were measured using an NE213 scintillator on top of the CHARM roof shielding where is the CERN Shielding Benchmark Facility (CSBF). The spectra were derived as fluences into the scintillator by the unfolding method using an iterative Bayesian algorithm. The methodology was verified based on the agreement of two spectra measured for different positions and directions of incident neutrons by changing the detector orientation. Since the spectra on the roof-top were obtained within a reasonable beam-time, this methodology is suitable for measuring the spectrum when there is less shielding material. Thus, experimental data for neutron transition can be obtained as a function of shielding thickness using this facility.
机译:为了建立CERN高能加速器混合场设施(CHARM)的中子谱测量方法,使用NEARM闪烁体在CHARM屋顶屏蔽顶部(即CERN屏蔽基准设施(CSBF))上测量中子谱。通过使用迭代贝叶斯算法的展开方法,将光谱作为注量导出到闪烁体中。通过改变探测器的方向,针对入射中子的不同位置和方向测量的两个光谱的一致性,验证了该方法的有效性。由于屋顶上的光谱是在合理的光束时间内获得的,因此该方法适用于在屏蔽材料较少的情况下测量光谱。因此,使用该设备可以获得中子跃迁的实验数据,作为屏蔽厚度的函数。