Clinical dosimetry in radiotherapy is a well known matter but high conformal radiotherapy modalities (Intensity Modulated Radiation Therapy (IMRT), stereotactic treatments with photons and protons. Intensity Modulated Proton Therapy (IMPT)) possess problems due to small radiation fields with high dose gradients, variation in space and time of the dose rate and variation in space and time of the beam energy spectrum. A modular dosimetric detector, adequate for 2D pre-treatment dose verifications, has been developed in the framework of the European Integrated project MAESTRO. The detector is a monolithic segmented sensor obtained by n-type implantation on a 50 uthick epitaxial silicon p-type layer; this is later used to guarantee improved radiation hardness of the device against the accumulated dose. The detector is composed of a matrix of 21 × 21 pixels with a size of 2 × 2 mm2 each and a 3 mm center-tocenter distance. A full dosimetric characterization of the detector was performed with photon and proton beams and with gammas from a~(60)Co unit. Results have been compared with those obtained with a Farmer and a CC13 Scanditronix/Welhoffer ion chamber as well as with the silicon matrix MapCHECK~™. The first application of the MAESTRO prototype in the dosimetric verification of a clinical IMRT field is also reported. Results show that our modular detector represents a valuable tool for quality assurance in IMRT dose delivery and for high precision radiotherapy techniques.
机译:放射治疗中的临床剂量测定是众所周知的问题,但是高保形放射治疗方式(强度调制放射治疗(IMRT),光子和质子的立体定向治疗。强度调制质子治疗(IMPT))由于辐射场小,剂量梯度高,剂量率的时空变化和射束能谱的时空变化。在欧洲综合项目MAESTRO的框架中,已经开发出了适合2D预处理剂量验证的模块化剂量检测器。该检测器是通过在50 ick厚的外延硅p型层上进行n型注入而获得的整体式分段传感器;后来用于确保针对累积剂量提高设备的辐射硬度。检测器由21×21像素的矩阵组成,每个像素的大小为2×2 mm2,中心距为3 mm。用光子和质子束以及α〜(60)Co单元的伽马值对探测器进行了全面的剂量学表征。将结果与使用Farmer和CC13 Scanditronix / Welhoffer离子室以及硅基质MapCHECKTM获得的结果进行了比较。还报道了MAESTRO原型在临床IMRT领域的剂量学验证中的首次应用。结果表明,我们的模块化检测器代表了IMRT剂量输送质量保证和高精度放射治疗技术的宝贵工具。

著录项

  • 来源
  • 作者单位

    University of Florence, Department of Clinical Physiopathology, Viale Morgagni 85, 50134 Firenze, Italy,INFN, Florence, Via G. Sansone 1, 50019 Sesto Fiorentino, Firenze, Italy,Azienda Ospedaliera Universitaria Careggi, Sezione di Fisica Medico, Viale Pieraccini, 50139 Firenze, Italy;

    INFN, Florence, Via G. Sansone 1, 50019 Sesto Fiorentino, Firenze, Italy,University of Florence, Department of Energetics, Via Santa Marta 3, 50139 Firenze, Italy;

    University of Florence, Department of Energetics, Via Santa Marta 3, 50139 Firenze, Italy;

    INFN, Florence, Via G. Sansone 1, 50019 Sesto Fiorentino, Firenze, Italy,University of Florence, Department of Energetics, Via Santa Marta 3, 50139 Firenze, Italy;

    INFN, Florence, Via G. Sansone 1, 50019 Sesto Fiorentino, Firenze, Italy,University of Florence, Department of Energetics, Via Santa Marta 3, 50139 Firenze, Italy;

    University of Florence, Department of Clinical Physiopathology, Viale Morgagni 85, 50134 Firenze, Italy,INFN, Florence, Via G. Sansone 1, 50019 Sesto Fiorentino, Firenze, Italy,Azienda Ospedaliera Universitaria Careggi, Sezione di Fisica Medico, Viale Pieraccini, 50139 Firenze, Italy;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    monolithic silicon detector; bidimensional dosimeter; IMRT verification;

    机译:单片硅探测器二维剂量计IMRT验证;
  • 入库时间 2022-08-18 00:48:06

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号