首页> 外文期刊>Nuclear Instruments & Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment >Improvement of radiation hardness of the sampling calorimeters based on plastic scintillators
【24h】

Improvement of radiation hardness of the sampling calorimeters based on plastic scintillators

机译:使用塑料闪烁体提高采样量热仪的辐射硬度

获取原文
获取原文并翻译 | 示例
获取外文期刊封面目录资料

摘要

Plastic scintillators are very often used as detecting media in sampling calorimeters of High Energy Physics (HEP). Many modern HEP experimental installations are already operating or proposed to work at high luminosity. Plastic scintillators are the most sensitive part of such setups in terms of their radiation hardness. Improving the light collection from the most irradiated scintillators will ensure their long-term use at high luminosity. The experimental results of the measurements for different assemblies (scintillator SCSN-81 and the WLS fiber Y-11 electron-irradiated (E≈4 MeV) were obtained. Calculations of the light yields for different samples based on our experimental results show the possibility of increasing the radiation hardness of plastic scintillators inside the sampling calorimeter up to 20 Mrad.
机译:塑料闪烁体通常用作高能物理(HEP)样品量热仪中的检测介质。许多现代的HEP实验装置已经在运行或提议在高亮度下工作。就其辐射硬度而言,塑料闪烁体是此类设置中最敏感的部分。改善大多数照射到的闪烁体的光收集将确保其在高亮度下长期使用。获得了对不同组件(闪烁体SCSN-81和WLS光纤Y-11电子辐照(E≈4MeV))进行测量的实验结果,根据我们的实验结果计算了不同样品的光通量,表明了将采样热量计内的塑料闪烁体的辐射硬度提高到20 Mrad。