A scintillator plate with high energy resolution was developed to produce an alpha particle monitor used in nuclear fuel reprocessing plants and mixed plutonium-uranium oxide (MOX) fuel plants. Grains of a Gd_2Si_2O_7 (GPS) scintillator of several 10 to 550 μm were fixed on a glass substrate and were then mechanically polished. By increasing the size of scintillator grains and removing fine powders, the collected light yield and energy resolution for alpha particles were drastically improved. Energy resolution of 9.3% was achieved using average grain size of 91 μm. Furthermore, the ratios between counts in a peak and total counts were improved by more than 60% by the further increase of grain size and adoption of mechanically polished surfaces on both sides. Beta and gamma ray influences were suppressed sufficiently by the thin 100 μm scintillator plates.
机译:开发了具有高能量分辨率的闪烁器板,以生产用于核燃料后处理厂和混合p铀氧化物(MOX)燃料厂的α粒子监测仪。将数为10至550μm的Gd_2Si_2O_7(GPS)闪烁体的晶粒固定在玻璃基板上,然后进行机械抛光。通过增加闪烁体晶粒的尺寸并去除细粉,大大提高了α粒子的收集光产率和能量分辨率。使用91μm的平均晶粒尺寸可实现9.3%的能量分辨率。此外,通过进一步增加晶粒尺寸和在两侧采用机械抛光表面,将峰数与总数之比提高了60%以上。薄的100μm闪烁体板充分抑制了beta和γ射线的影响。