首页> 外文期刊>Nuclear Instruments & Methods in Physics Research >The quality of megavoltage photon beams measured by the ratio of photoactivation and neutron capture yields
【24h】

The quality of megavoltage photon beams measured by the ratio of photoactivation and neutron capture yields

机译:通过光活化和中子俘获率的比值测量兆伏光子束的质量

获取原文
获取原文并翻译 | 示例
获取外文期刊封面目录资料

摘要

The activities of products of two photonuclear reactions (113In(γ,γ’)113mIn and115In(γ,γ’)115mIn) and neutron capture (115In(n,γ)116mIn) were measured. The measurements were made to verify that obtained activities (as well as some of their ratios) change sufficiently with the change of the energy, so that the activation of the indium could be recommended as a sensitive test for the control of the endpoint energy (and beam quality) of bremsstrahlung beams in an energy region usually used in radiation therapy. Mikrotron photon beam was used for photoactivation, and the source of neutrons was the mikrotron tungsten target itself, at energies higher than threshold for (γ, n) reaction. At lower energies, neutrons were produced in Be target inserted in photon beam. It was obtained that sensitive index of endpoint energy variation can be obtained in a broad energy region from 5 MeV to 23 MeV by different combinations of saturation activities of three reaction products. The described measurements can be used to develop a very sensitive and simple method in a routine quality control of photon beams of megavoltage devices used in radiotherapy.
机译:测量了两个光核反应(113In(γ,γ')113mIn和115In(γ,γ')115mIn)和中子俘获(115In(n,γ)116mIn)产物的活性。进行测量以验证所获得的活性(及其某些比率)随能量的变化而充分变化,因此可以建议将铟的活化作为控制终点能量(和通常在放射治疗中使用的能量区域中的致辐射光束。用Mikrotron光子束进行光活化,中子源是mikrotron钨靶本身,能量高于(γ,n)反应阈值。在较低的能量下,插入光子束的Be目标中产生了中子。通过三种反应产物的饱和活性的不同组合,可以得到从5 MeV到23 MeV的宽能量区域的终点能量变化的敏感指数。所描述的测量结果可用于在放射治疗中所用兆电压设备的光子束的常规质量控制中开发出一种非常灵敏且简单的方法。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号