摘要

Oak Ridge National Laboratory has started monitoring HFIR cooling fans with wireless vibration sensors. The sensors are conventional accelerometers that are connected with a few feet of wire to a wireless hub. At each 6-hour interval, 30 seconds of real-time vibration data is collected from each of the three sensors per motor (there are four motors for the four cooling tower fans). The data is then transmitted wirelessly from the remote data acquisition unit at the cooling towers to the HFIR server, around 250 feet away. Each time that data is collected, vibration statistics are calculated and on-going trends are updated. The server software application provides a "Green - Yellow - Red" visual alert for each motor.
机译:橡树岭国家实验室(Oak Ridge National Laboratory)已开始使用无线振动传感器监控HFIR冷却风扇。传感器是传统的加速度计,通过几英尺的导线连接到无线集线器。每隔6小时,每台电动机的三个传感器中的每个传感器将收集30秒的实时振动数据(四个冷却塔风扇有四个电动机)。然后,数据从冷却塔处的远程数据采集单元无线传输到大约250英尺远的HFIR服务器。每次收集数据时,都会计算振动统计信息并更新持续的趋势。服务器软件应用程序为每个电动机提供“绿色-黄色-红色”视觉警报。