首页> 外文期刊>Nuclear Engineering and Design >Liquid entrainment and off-take through the break at the top of a vessel
【24h】

Liquid entrainment and off-take through the break at the top of a vessel

机译:容器顶部的液体夹带和排出

获取原文
获取原文并翻译 | 示例
       

摘要

In order to determine the bleed capacity of the safety depressurization system (SDS) of Advanced Power Reactor 1400 (APR 1400) in the case of total loss of feed water (TLOFW), we performed an experimental study of liquid entrainment and liquid off-take from the swelled two-phase mixture surface in a vessel. A total of 220 experimental data on the entrainment and off-take are obtained using a test vessel with a height of 2.0 m and an inner diameter of 0.3 m and a top break with a diameter of 0.05 m. Two-phase mixture levels are measured by an ultrasonic sensor within ± 1.77% with respect to the visual level data. Droplet entrainment data are obtained with and without the top break and are compared with the existing pool entrainment data. The present droplet entrainment data have higher values than the existing pool entrainment data due to (a) the pulling toward the break of the liquid deentrained on the top wall of the vessel and (b) gas acceleration in the vicinity of the break. In the present experiment, droplet entrainment, E_(fg), strongly depends upon j_g~*/h~* and is proportional to the seventh power of j_g~*/ h~* in the same way as the off-take data. The empirical correlation for the onset of off-take is developed in terms of the Froude number (Fr_g) at the break and the non-dimensional inception height (h_b/d). This correlation shows agreement with the present experimental data within ±15%. The present off-take quality data show agreement with Schrock's off-take quality correlation with the rms error of 15.8%.
机译:为了确定在给水完全丧失(TLOFW)的情况下,先进动力反应堆1400(APR 1400)的安全降压系统(SDS)的放气容量,我们进行了液体夹带和液体排出的实验研究从容器中溶胀的两相混合物表面流出。使用高度为2.0 m,内径为0.3 m且顶部断裂直径为0.05 m的试验容器,可获得关于夹带和释放的总共220个实验数据。相对于视觉水平数据,两相混合物水平由超声波传感器测量在±1.77%之内。在有或没有顶部中断的情况下获得液滴夹带数据,并将其与现有池夹带数据进行比较。当前的液滴夹带数据具有比现有的池夹带数据更高的值,这是由于以下原因:(a)将夹带在容器顶壁上的液体拉向破裂的拉力,以及(b)破裂附近的气体加速。在本实验中,液滴夹带E_(fg)强烈取决于j_g〜* / h〜*,并与脱模数据相同,与j_g〜* / h〜*的七次方成正比。根据中断时的弗洛伊德数(Fr_g)和无量纲起始高度(h_b / d),得出了开始承购的经验相关性。这种相关性表明与当前实验数据的吻合度在±15%之内。当前的承购质量数据表明与Schrock的承购质量相关性一致,均方根误差为15.8%。

著录项

  • 来源
    《Nuclear Engineering and Design》 |2005年第16期|p.1675-1685|共11页
  • 作者

    Chang Hyun Kim; Hee Cheon No;

  • 作者单位

    Korea Atomic Energy Research Institute (KAERI), P.O. Box 105, Yuseong-gu, Daejeon 305-600, Rep. of Korea;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);美国《生物学医学文摘》(MEDLINE);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类 原子能技术;
  • 关键词

  • 入库时间 2022-08-18 00:47:30

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号