Study on the passive refrigeration for main control room of nuclear power plant in power outage accident

机译:停电事故中核电厂主控制室的被动制冷研究

获取原文
获取原文并翻译 | 示例
           

摘要

High-pressure air with room temperature can be used for refrigeration through isentropic expansion or isenthalpic throttling process with no power supplying, which can also meet the demands of oxygen supplying for operators in the insulated situation. Two passive cooling strategies for high-pressure air are proposed: one is throttling refrigeration, and the other is expansion refrigeration, which can provide an effective method to ensure the safety of operators in main control room when an emergency occurs in nuclear power plant. Comparisons between the two passive cooling strategies are done by theoretical and experimental methods, and the cooling effects for both strategies are analyzed. The results show that the passive cooling strategy of isentropic expansion can meet the both requirements of cooling and clean air supplying for the main control room when emergencies occur in nuclear plants, with the minimum cooling capacity of 3000 W.
机译:室温高压空气可通过等熵膨胀或等焓节流过程用于制冷,无需供电,也可满足绝热情况下操作人员的供氧需求。提出了两种高压空气的被动冷却策略:一种是节流制冷,另一种是膨胀制冷,可以为确保核电站发生紧急情况时确保主控制室操作人员的安全提供有效的方法。通过理论和实验方法对两种被动冷却策略进行了比较,并分析了两种策略的冷却效果。结果表明,当核电厂发生紧急情况时,等熵膨胀的被动冷却策略既可以满足主控制室的冷却需求,又可以满足清洁空气供应的要求,最小冷却能力为3000W。

著录项

  • 来源
    《Nuclear Engineering and Design》 |2018年第1期|183-189|共7页
  • 作者单位

    Chongqing Univ, Coll Power Engn, Minist Educ PRC, Key Lab Low Grade Energy Utilizat Technol & Syst, 174 Shazheng St, Chongqing 400044, Peoples R China;

    Chongqing Univ, Coll Power Engn, Minist Educ PRC, Key Lab Low Grade Energy Utilizat Technol & Syst, 174 Shazheng St, Chongqing 400044, Peoples R China;

    Chongqing Univ, Coll Power Engn, Minist Educ PRC, Key Lab Low Grade Energy Utilizat Technol & Syst, 174 Shazheng St, Chongqing 400044, Peoples R China;

    Wuhan Branch Shanghai GM, Dept Purchasing, 8 GM St, Wuhan 430200, Hubei, Peoples R China;

    Chongqing Univ, Coll Power Engn, Minist Educ PRC, Key Lab Low Grade Energy Utilizat Technol & Syst, 174 Shazheng St, Chongqing 400044, Peoples R China;

    Chongqing Univ, Coll Power Engn, Minist Educ PRC, Key Lab Low Grade Energy Utilizat Technol & Syst, 174 Shazheng St, Chongqing 400044, Peoples R China;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);美国《生物学医学文摘》(MEDLINE);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    High pressure air; Passive cooling strategy; Throttling refrigeration; Expansion refrigeration; Main control room of nuclear power plant;

    机译:高压空气;被动冷却策略;节流制冷;膨胀制冷;核电厂主控制室;