In light water reactors, particularly the pressurized water reactor (PWR), the severity of a loss of coolant accident (LOCA) will limit how high the reactor power can operate. Although the best-estimate LOCA licensing methodology can provide the greatest margin on the PCT evaluation during LOCA, it generally takes more resources to develop. Instead, implementation of evaluation models required by Appendix K of 10 CFR 50 upon an advanced thermal-hy- raulic platform also can gain significant margin for the PCT calculation. The compliance of the current RELAP5-3D code with Appendix K of 10 CFR 50 has been evaluated, and it was found that there are ten areas where code assessment and/or further modifications were required to satisfy the requirements set forth in Appendix K of 10 CFR 50.
机译:在轻水反应器中,特别是加压水反应器(PWR),冷却剂事故(LOCA)丧失的严重程度将限制反应器功率如何运行。虽然最佳估算的LOCA许可方法可以在LOCA期间提供最大的PCT评估保证金,但它通常需要更多资源开发。相反,在高级热速平台上,10 CFR 50的附录K所需的评估模型的实现也可以获得PCT计算的显着余量。已经评估了10 CFR 50附录K的当前RELAP5-3D代码的遵守,并发现有十个区域需要代码评估和/或进一步修改以满足10的附录K中所规定的要求CFR 50。