摘要

During mercury intrusion at low pressure into uncoated and pigment-coated papers, irreproducible large pore volumes are frequently recorded which prevent detailed determination of total composite porosity by mercury porosimetry alone. A novel occlusion-correction procedure is reported here, in which the absorption volume of hexadecane into the void structures and its displacement by the skeletal structures are combined with the mercury intrusion data to allow the coating and the substrate to be separately assessed. This may be achieved either directly, in the case of a non-permeable substrate, or by scaling the intrusion into the uncoated permeable substrate to that of the coated substrate intrusion curve. This is then scaled to an absolute porosity and bulk volume of the coated sample. The values so derived are compared to those obtained by the traditional method of approximating the intrusion volume into the coating and to the coating applied to an aluminium foil substrate. A method for estimating coating coverage derived from these analyses is described.
机译:在低压下将汞压入未涂布纸和颜料涂布纸的过程中,经常记录到无法再现的大孔体积,这妨碍了仅通过水银孔隙率法详细测定总复合孔隙率。本文报道了一种新颖的吸留校正程序,其中十六烷在空隙结构中的吸收量及其在骨架结构中的位移与汞侵入数据结合在一起,可以分别评估涂层和基材。在非渗透性基材的情况下,这可以直接实现,也可以通过将未涂覆的渗透性基材中的浸入比例缩放为涂覆的基材浸入曲线的浸入。然后将其缩放至涂层样品的绝对孔隙率和体积。将由此得出的值与通过传统方法得出的值进行比较,这些方法是近似逼近涂层中的侵入体积,并与应用于铝箔基材的涂层进行比较。描述了一种从这些分析得出的估计涂层覆盖率的方法。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号