We present an overview of the OSIRIS integral field spectrograph which was recently commissioned on the Keck II Telescope. OSIRIS works with the Keck Adaptive Optics system and utilizes an infrared transmissive lenslet array to sample a rectangular field of view at close to the Keck diffraction limit. By packing the spectra very closely together (2 pixel rows per spectrum) and using the Rockwell Hawaii-2 detector (wavelengths between 1 and 2.5 μm), we achieve a relatively large field of view (up to 6.4") while maintaining full broad-band spectral coverage at a resolution of 3800. Among the challenges of the instrument are: a fully cryogenic design (approximately 250 kg are brought down to 55 K); four spatial scales from 0.02 to 0.10"; extremely low wavefront error (approximately 25 nm of non-common path error); large all aluminum optics for the spectrograph; extremely repeatable spectral formats; and a sophisticated data reduction pipeline.
机译:我们将介绍OSIRIS积分现场光谱仪的概述,该光谱仪最近在Keck II望远镜上进行了调试。 OSIRIS与Keck自适应光学系统配合使用,并利用红外透射小透镜阵列对接近Keck衍射极限的矩形视场进行采样。通过将光谱非常紧密地排列在一起(每个光谱2个像素行),并使用Rockwell Hawaii-2检测器(波长介于1和2.5μm之间),我们可以在保持全宽光谱的同时获得相对较大的视场(最大6.4英寸)。该仪器的挑战包括:完全低温的设计(将约250 kg降低到55 K);四个空间比例从0.02到0.10“;波前误差极低(非公共路径误差约为25 nm);用于光谱仪的大型全铝光学器件;可重复的光谱格式;以及完善的数据缩减管道。