The lift-off effect is commonly known to be one of the main obstacles for effective eddy current NDT testing as it can easily mask defect signals. Pulsed eddy current techniques, which are believed to be potentially rich of information, are also sensitive to the effect. An approach using normalisation and two reference signals to reduce the lift-off problem with pulsed eddy current techniques is proposed. Experimental testing on the proposed technique and results are presented in this report. Results show that significant reduction in the effect has been achieved mainly in metal loss and sub-surface slot inspection. The technique can also be applied for measurement of metal thickness beneath non-conductive coatings, microstructure, strain/stress measurement, where the output is sensitive to the lift-off effect.
机译:众所周知,剥离效应是有效进行涡流NDT测试的主要障碍之一,因为它很容易掩盖缺陷信号。脉冲涡流技术据信可能具有丰富的信息,但对这种影响也很敏感。提出了一种利用归一化和两个参考信号减少脉冲涡流技术的提离问题的方法。本报告介绍了对所提出的技术和结果的实验​​测试。结果表明,主要在金属损失和表面下缝隙检查中,效果已大大降低。该技术还可用于测量非导电涂层下的金属厚度,微结构,应变/应力测量,其中输出对剥离效应敏感。