The objective of this study was to develop a practical solution for detecting the void spaces beneath the concrete face slab of a rockfill dam using the damping ratio measured at the top surface of the concrete face slab. The damping ratio acted as an indicator of energy leakage at the bottom surface of the concrete face slab and provided a basis for detecting void spaces. The damping ratio was rapidly and accurately measured using the wave-group resonance identification technique. Finally, the proposed method was validated through coring at a concrete-faced rockfill dam in Korea.
机译:本研究的目的是开发一种实用的解决方案,用于使用在混凝土面板的顶表面上测量的阻尼比来检测堆石坝的混凝土面板下方的空隙空间。阻尼比用作混凝土面板底表面的能量泄漏指示器,并为检测空隙空间提供了基础。使用波组谐振识别技术快速准确地测量阻尼比。最后,通过在韩国的混凝土堆石坝的芯片上验证了所提出的方法。

著录项

  • 来源
    《NDT & E international》 |2021年第3期|102395.1-102395.10|共10页
  • 作者单位

    Department of Civil and Environmental Engineering Chung-Ang University 84 HeukSeok-Ro Dongjak-Gu Seoul 06974 South Korea;

    Department of Civil and Environmental Engineering Chung-Ang University 84 HeukSeok-Ro Dongjak-Gu Seoul 06974 South Korea;

    Department of Civil and Environmental Engineering Chung-Ang University 84 HeukSeok-Ro Dongjak-Gu Seoul 06974 South Korea;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    Void space; Damping ratio; Concrete face slab; Resonance test; Leaky surface wave;

    机译:空间;阻尼比;混凝土面板;共振测试;漏水表面波;
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号