首页> 外文期刊>National Engineer >COMPRESSED AIR SYSTEM MODIFICATIONS IMPROVE EFFICIENCY AT A PLASTICS BLOW MOLDING PLANT
【24h】

COMPRESSED AIR SYSTEM MODIFICATIONS IMPROVE EFFICIENCY AT A PLASTICS BLOW MOLDING PLANT

机译:压缩空气系统修改可提高塑料吹塑厂的效率

获取原文
获取原文并翻译 | 示例

摘要

In 1997, Southeastern Container performed modifications to the compressed air system at their blow molding plant in Enka, North Carolina. The project was based on a survey of the plant's compressed air system performed by North Carolina State University's (NCSU) Industrial Extension Service. The project allowed the plant's compressed air system to operate more efficiently, which resulted in significant compressed air energy savings and better production. The total energy savings from the implementation of the modifications were $180,000 (7,400,000 kWh) per year, which represent over 16% of their compressed air electricity costs. In addition, maintenance costs were reduced by approximately 75%. Because the project's cost was $80,000, the simple payback was less than 6 months.
机译:1997年,Southeastern Container在北卡罗来纳州恩卡的吹塑厂对压缩空气系统进行了修改。该项目基于北卡罗来纳州立大学(NCSU)工业推广服务对工厂压缩空气系统进行的调查。该项目使工厂的压缩空气系统更有效地运行,从而显着节省了压缩空气的能源并提高了产量。实施这些修改每年可节省的总能量为180,000美元(7,400,000 kWh),占其压缩空气电力成本的16%以上。此外,维护成本降低了约75%。由于该项目的成本为80,000美元,因此简单的投资回收期不到6个月。