This paper investigates the efficiency of Tuned Liquid Dampers (TLDs) in mitigating dynamic responses of vertically irregular structures. For this purpose, a three-story steel structure was specifically designed and subjected to free and forced vibration tests. In addition, the dynamic responses of eight structure-TLD systems were investigated through three cases. In the first and second cases, TLDs were tuned to the first and second natural frequencies of the steel structure and they were installed on each floor separately. In the third case, which was referred to as the combined case, two TLDs that were tuned to the first and second natural frequencies were first placed simultaneously on the third floor and then separately on the third and second floors. The results indicated that the installation of the combined TLDs on the third floor reduced the peak acceleration and displacement responses of the third floor more than the other cases. It was also observed that, in all the studied cases, the peak displacement response of the third floor was significantly increased when the structure-TLD systems were excited at the second resonance frequency. In addition, at the second resonance frequency, the TLD which was tuned to the first natural frequency and installed at the third floor increased the peak acceleration responses of all floors. It was concluded that, unlike the case in regular structures, a TLD which is tuned to the first natural frequency and installed at the highest level of an irregular structure may not satisfactorily mitigate the structural response of all floors. (C) 2018 Elsevier Ltd. All rights reserved.
机译:本文研究了可调液体阻尼器(TLD)在缓解垂直不规则结构动力响应方面的效率。为此,专门设计了三层钢结构,并进行了自由和强制振动测试。此外,通过三个案例研究了八个结构TLD系统的动态响应。在第一种和第二种情况下,将TLD调整到钢结构的第一和第二固有频率,并将它们分别安装在每个地板上。在第三种情况(称为合并情况)中,两个调谐到第一和第二固有频率的TLD首先同时放置在第三层,然后分别放置在第三层和第二层。结果表明,与其他情况相比,在三层安装组合式TLD降低了三层的峰值加速度和位移响应。还观察到,在所有研究情况下,当结构-TLD系统在第二共振频率下激发时,第三层的峰值位移响应都显着增加。此外,在第二共振频率处,TLD调谐到第一固有频率并安装在第三层,这增加了所有层的峰值加速度响应。得出的结论是,与常规结构不同,TLD调谐到第一个自然频率并安装在不规则结构的最高级别可能无法令人满意地减轻所有楼层的结构响应。 (C)2018 Elsevier Ltd.保留所有权利。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号