首页> 外文期刊>Measurement techniques >ESTIMATE OF THE RATIO OF THE DATA AND BACKGROUND SIGNALS IN DETECTING THE MAGNETIC FIELDS OF SURFACE DEFECTS BY MAGNETIC MEASUREMENT TRANSDUCERS
【24h】

ESTIMATE OF THE RATIO OF THE DATA AND BACKGROUND SIGNALS IN DETECTING THE MAGNETIC FIELDS OF SURFACE DEFECTS BY MAGNETIC MEASUREMENT TRANSDUCERS

机译:估计磁力测量换能器检测表面缺陷磁场的数据和背景信号的比率

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

The problems of identifying defective segments of the surface of monitored objects and estimating the parameters of the defects are examined. The use of magnetic measurement transducers is described as a means of detecting and measuring the parameters of the locally distributed magnetic fields which appear above defective segments of the surface of a monitored object in an applied constant magnetic field. Algorithms are proposed for quantitative evaluation of the ratio of the data and background components of the output signal from magnetic measurement transducers. A method is derived for separating the data and background components. It is based on the summation property and the determined character of the distributions of the magnetic field intensity of a defect and the background magnetic field along the coordinate axis parallel to the monitored surface and on an analysis of the topography of the distribution of the magnetic field intensity. The approach to the choice and experimental definition of the estimated parameters characterizing the level of the data and background signals is validated. Formulas are given for calculating the signal-to-background ratio from the measured estimates for ordinary magnetostatic, differential magnetostatic and differentiating magnetic measurement measurement transducers taking into account the direction of orientation (normal, tangential) of their sensitivity axis. The signal-to-background ratio of a transducer is calculated for the example of the output signal from a magnetic measurement transducer during detection of the distribution of the magnetic field intensity over the surface of a monitored sample with artificial defects of specified sizes. A comparative analysis is made of these kinds of magnetic measurement transducers in terms of their signal-to-background ratio and general recommendations are made for increasing that ratio.
机译:检查了监测对象表面缺陷段和估计缺陷参数的问题。使用磁性测量换能器被描述为检测和测量局部分布磁场的参数的方法,该磁场出现在施加的恒定磁场中被监视物体表面的缺陷段。提出了算法,用于定量评估来自磁测量换能器的输出信号的数据和背景分量的比率。导出用于分离数据和背景组件的方法。基于求和性质和磁场强度的分布特征,缺陷的磁场强度和沿着监测表面平行的坐标轴的背景磁场以及对磁场分布分布的地形的分析强度。验证了表征数据和背景信号水平的估计参数的选择和实验定义的方法。考虑到它们灵敏度轴的定向方向(正常,切线)的方向,给出了从测量的普通磁静压,差动磁静电和区分磁测量换能器的测量的估计来计算的公式。在检测到通过特定尺寸的人工缺陷的监测样品的表面的磁场强度的分布检测期间,计算换能器的示例的换能器的信号 - 背景比。在其信号到背景比率方面,对这些种类的磁性测量换能器进行了比较分析,并且对增加该比例进行了一般性建议。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号