首页> 外文期刊>Materials science & engineering >Corrosion resistance characteristics of a Ti-6Al-4V alloy scaffold that is fabricated by electron beam melting and selective laser melting for implantation in vivo
【24h】

Corrosion resistance characteristics of a Ti-6Al-4V alloy scaffold that is fabricated by electron beam melting and selective laser melting for implantation in vivo

机译:通过电子束熔化和选择性激光熔化制备的用于体内植入的Ti-6Al-4V合金支架的耐腐蚀特性

获取原文
获取原文并翻译 | 示例
           

摘要

The purpose of this study is to determine the corrosion resistance of Ti-6Al-4V alloy fabricated with electron beam melting and selective laser melting for implantation in vivo. Ti-6Al-4V alloy specimens were fabricated with electron beam melting (EBM) and selective laser melting (SLM). A wrought form of Ti-6Al-4V alloy was used as a control. Surface morphology observation, component analysis, corrosion resistance experimental results, electrochemical impedance spectroscopy, crevice corrosion resistance experimental results, immersion test and metal ions precipitation analysis were processed, respectively. The thermal stability of EBM specimen was the worst, based on the result of open circuit potential (OCP) result The result of electrochemical impedance spectroscopy indicated that the corrosion resistance of the SLM specimen was the best under the low electric potential. The result of potentiodynamic polarization suggested that the corrosion resistance of the SLM specimen was the best under the low electric potential (<1.5 V) and EBM specimen was the best under the high electric potential (>1.5 V).The crevice corrosion resistance of the EBM specimen was the best The corrosion resistance of SLM specimen was the best, based on the result of immersion test. The content of Ti, Al and V ions of EBM, SLM and wrought specimens was very low. In general, the scaffolds that were fabricated with EBM and SLM had good corrosion resistance, and were suitable for implantation in vivo.
机译:这项研究的目的是确定通过电子束熔化和选择性激光熔化制造的用于体内植入的Ti-6Al-4V合金的耐腐蚀性。用电子束熔化(EBM)和选择性激光熔化(SLM)制成Ti-6Al-4V合金样品。使用变形形式的Ti-6Al-4V合金作为对照。分别进行了表面形态观察,成分分析,耐腐蚀性实验结果,电化学阻抗谱,缝隙耐腐蚀性实验结果,浸没试验和金属离子沉淀分析。基于开路电势(OCP)结果,EBM样品的热稳定性最差。电化学阻抗谱的结果表明,SLM样品在低电势下的耐蚀性最佳。电位动力极化的结果表明,在低电位(<1.5 V)下,SLM试样的耐蚀性最佳,在高电位(> 1.5 V)下,EBM试样的耐蚀性最好。根据浸没试验的结果,EBM样品最好。SLM样品的耐腐蚀性最好。 EBM,SLM和变形试样的Ti,Al和V离子含量很低。通常,用EBM和SLM制成的支架具有良好的耐腐蚀性,并且适合在体内植入。

著录项

  • 来源
    《Materials science & engineering》 |2017年第1期|832-841|共10页
  • 作者单位

    Department of Stomatology, General Hospital of the PLA, Beijing, China,Department of Stomatology, The Second Affiliated Stomatological Hospital of Liaoning Medical University, China;

    Department of Stomatology, General Hospital of the PLA, Beijing, China,Department of Stomatology, The Second Affiliated Stomatological Hospital of Liaoning Medical University, China;

    College of Materials Science and Engineering, Beijing University of Chemical Technology, Beijing, China;

    School of Medicine, Nankai University, Tianjin 300071, China;

    Department of Stomatology, General Hospital of the PLA, 28 Fuxing Road, Haidian District, Beijing 100853, China;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    Selective laser melting (SLM); Electron beam melting (EBM); Corrosion resistance; Ti-6Al-4V; Implants;

    机译:选择性激光熔化(SLM);电子束熔化(EBM);耐腐蚀性能;Ti-6Al-4V;植入物;

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号