Failure of a tubular heat exchanger made up of copper based alloys in a steam power plant was investigated. Tubes were made initially from yellow brass, and there after replaced by Cu-5Ni alloys. Circulating water from cooling tower was used as coolant, to condense the hot steam inside the steel shell. The velocity of cooling water was found to be very low, causing accumulation of deposits, reduction of diameter and some times complete blockage of tubes. The causes of failure were investigated performing various tests such as chemical analysis, XRD, optical, and SEM examination. Study revealed that tube material suffering from extensive dealloying and impingement attack.
机译:研究了蒸汽发电厂中由铜基合金制成的管状热交换器的故障。管子最初是用黄色黄铜制成的,然后用Cu-5Ni合金代替。来自冷却塔的循环水用作冷却剂,以冷凝钢壳内的热蒸汽。发现冷却水的速度非常低,导致沉积物积聚,直径减小,有时还会完全堵塞管子。通过执行各种测试(例如化学分析,XRD,光学和SEM检查)来调查故障原因。研究表明,管材遭受广泛的脱合金和撞击攻击。