首页> 外文期刊>IEEE transactions on components, packaging, and manufacturing technology. Part A >Forced convection air-cooling of a commercial electronic chassis: an experimental and computational case study
【24h】

Forced convection air-cooling of a commercial electronic chassis: an experimental and computational case study

机译:商用电子机箱的强制对流风冷:实验和计算案例研究

获取原文
获取原文并翻译 | 示例
           

摘要

The present study examines the suitability of a combined experimental and computational methodology for system-level electronic packaging thermal design. A 48.3 cm (19 in), twenty-slot, fully populated commercial-off-the-shelf (COTS) electronic equipment chassis was studied experimentally and computationally. The experimental program involved detailed component surface temperature measurements for system power levels of 423 and 846 W (21 and 42 W/module) and for volumetric flow rates between 0.05 and 0.14 m/sup 3//s. The experimental configuration was also computationally simulated and the predicted component temperatures agreed well with the experiments. The effects of various baffle configuration designs within the inlet plenum were then computationally analyzed for improved thermal performance. The best configuration based on the model study was experimentally examined and provided maximum surface temperature reduction of 56%.
机译:本研究检查了结合实验和计算方法的系统级电子包装热设计的适用性。通过实验和计算研究了一个48.3厘米(19英寸),二十个插槽,完全填充的现成商用(COTS)电子设备机箱。该实验程序涉及详细的组件表面温度测量,用于系统功率水平423和846 W(21和42 W /模块)以及体积流量在0.05和0.14 m / sup 3 // s之间。还通过计算模拟了实验配置,预测的组件温度与实验吻合得很好。然后对进气室内各种挡板配置设计的影响进行了分析,以提高热性能。实验研究了基于模型研究的最佳配置,该配置可将最大表面温度降低56%。