首页> 外文期刊>Magazine of Concrete Research >Behaviour of concrete columns with drilled holes
【24h】

Behaviour of concrete columns with drilled holes

机译:钻孔混凝土柱的性能

获取原文
获取原文并翻译 | 示例
       

摘要

Holes drilled out to install additional services or equipment, such as for ducts through columns, beams or walls, can lead to loss of strength and possible structural failure. Until now little work has been done on holes in columns and, hence, the present study aims to examine the amount of strength lost owing to the presence of holes in columns. The reported experimental work deals with different parameters such as the number and dimensions of the holes and their relative position. It is shown that, for large diameter holes, a section capacity loss of up to 50% is possible.
机译:钻出孔来安装其他服务或设备,例如,穿过圆柱,横梁或墙的管道,可能会导致强度损失和可能的结构故障。到目前为止,在圆柱孔上所做的工作很少,因此,本研究旨在检查由于圆柱孔而造成的强度损失。报道的实验工作涉及不同的参数,例如孔的数量和尺寸及其相对位置。结果表明,对于大直径的孔,截面容量损失可能高达50%。