【24h】

Initial conditioning of the TFTR vacuum vessel

机译:TFTR真空容器的初始调节

获取原文

摘要

We report on the initial conditioning of the Tokamak Fusion Test Reactor (TFTR) vacuum vessel prior to the initiation of first plasma discharges, and during subsequent operation with high power Ohmically heated plasmas. Following evacuation of the 86‐m3 vessel with the 104 1/s high vacuum pumping system, the vessel was conditioned by a 15‐A dc glow discharge in H2 at a pressure of 5 mTorr. Rapid‐pulse discharge cleaning was used subsequently to preferentially condition the graphite plasma limiters. The effectiveness of the discharge cleaning was monitored by measuring the exhaust rates of the primary discharge products (CO/C2H4, CH4, and H2O). After 175 h of glow discharge treatment, the equivalent of 50 monolayers of C and O was removed from the vessel, and the partial pressures of impurity gases were reduced to the range of 10-9–10-10 Torr.
机译:我们报告了托卡马克聚变测试反应堆(TFTR)真空容器在开始首次等离子体放电之前以及在随后的大功率欧姆加热等离子体操作过程中的初始条件。用104 1 / s高真空泵系统抽空86-m3容器后,通过在5 mTorr的压力下在H2中进行15-A dc辉光放电对容器进行调节。随后使用快速脉冲放电清洗来优先调节石墨等离子限制器。通过测量一次放电产物(CO / C2H4,CH4和H2O)的排气速率来监控放电清洁的有效性。经过175小时的辉光放电处理后,从容器中取出了50个单层的C和O,并将杂质气体的分压降低到10-9-10-10 Torr的范围。